Antminer Liquid Cooling in Standard Racks — 3U High Density · Cold Plate Heat Exchange · Water-Electricity Isolation
Product Overview
The Antminer 3U 13-Bay Liquid Cooling Unit is Xinke Intelligent’s standard rack-mount liquid cooling solution for blockchain mining farms, with a 3U standard size carrying 13 Antminer miners and installing directly into standard cabinets and racks for high-density, standardized indoor liquid cooling deployment. It carries the core genes of the Antminer-compatible series: Bitmain-certified components (Linko aviation plugs, Chint electrical), 304 stainless steel piping and a water-electricity isolation design ensure safety and stability from connections to piping and from electrical to hydraulic systems.
The unit uses cold plate heat exchange to keep miners at stable temperatures under full load, free from traditional air cooling noise and heat buildup; multiple units combine in standard racks to form full-rack liquid cooling, and work with liquid cooling cabinets, containers and CDUs to cover everything from single racks to whole farms — the ideal way to upgrade existing standard racks to liquid cooling quickly.
Key Features
01 3U Standard Size, 13-Bay High-Density Capacity: 3U standard rack-mount design carrying 13 Antminer miners, installing directly into standard cabinets and racks for high-density liquid cooling deployment in limited space.
02 Cold Plate Heat Exchange, Quiet & Efficient: Cold plate liquid cooling efficiently removes miner heat with stable temperatures under full load — no fan noise, no airflow hot spots, quieter and more stable computing.
03 Bitmain-Certified Components, OEM Quality Assurance: Uses Bitmain-certified components: Linko aviation plugs and Chint electrical, with interface compatibility and component quality backed by the OEM, remaining stable and reliable under sustained full-load operation.
04 Water-Electricity Isolation Design, Safe Operation: Water and electrical circuits are physically isolated to eliminate cross-contamination safety hazards, protecting miners and operators through high-intensity, long-duration operation.
05 304 Stainless Steel Piping, Clean & Contaminant-Free: Piping in 304 stainless steel keeps the system clean, corrosion-resistant and contaminant-free, safeguarding coolant quality with no scaling or leakage over time.
06 Standard Rack Deployment, Easy Install & Maintain: 3U standard size fits universal cabinets with neat, simple installation; each unit is independently grouped so miner installation and maintenance do not interfere.
07 Flexible Combination, On-Demand Expansion: Multiple units combine in standard racks and scale with mining size; works with liquid cooling cabinets, containers and CDUs to build a complete liquid cooling system.
08 Precision Manufacturing, Full-Lifecycle Service: ISO9001 quality system with four-stage inspection and ±0.1mm precision; 2-year warranty with 7×24 response and 365-day free on-site service in China.
Technical Specifications
| Parameter | Specification |
| Product Positioning | 3U standard rack-mount liquid cooling unit (for Antminer miners) |
| Bay Capacity | 13 bays (compatible with mainstream Antminer models) |
| Mounting Form | 3U standard size, installs in standard cabinets/racks |
| Cooling Form | Cold plate liquid cooling heat exchange |
| Piping Material | 304 stainless steel piping (clean, corrosion-resistant) |
| Key Components | Bitmain-certified: Linko aviation plugs, Chint electrical |
| Safety Design | Water-electricity isolation, physically separated circuits |
| Smart Management | Optional XINKE SMART (unattended) |
| Safety Protection | Optional leak detection and alarm |
| Expansion | Multi-unit combination in standard racks, on-demand scaling |
| Application | Standard-rack liquid cooling in mining facilities |
| Warranty | 2 years, 7×24 service response |
Note: Typical configuration parameters; the final specification is subject to the customized project solution.
Working Principle & System Positioning
The Antminer 3U 13-Bay Unit installs into standard racks to form a cold plate liquid cooling loop: miner heat is transferred to the coolant via cold plates, 304 stainless steel piping delivers the coolant to the rack-level CDU/pump station, and outdoor heat rejection terminals dissipate it to the environment; water-electricity isolation ensures electrical safety and the smart management system monitors operating status in real time. Multiple units form full-rack, full-row liquid cooling, working with cabinets and containers to complete the Antminer product matrix and help mines enter liquid cooling at a lower threshold.
Applications
- High-density liquid cooling of Antminer miners in standard racks
- Modular liquid cooling construction in mining farm computer rooms
- Smooth upgrade of traditional air-cooled computer rooms to liquid cooling
- Rapid liquid cooling adoption for small-to-medium mining farms
- Scaled deployment combined with liquid cooling cabinets and containers
Services & Warranty
- 2-year warranty with 7×24 service response
- 365-day free on-site service in China, covering the full project lifecycle
- Fully customizable: form factor, features, appearance and piping layout
- Standard products delivered in 7-15 days; large custom projects in 30-45 days
- Products delivered to 30+ countries and regions worldwide