All-Scenario Computing Delivery Unit — Modular Integration · Plug-and-Play · Rapid Indoor & Outdoor Deployment
Product Overview
The Data Center Computing Container is Xinke Intelligent’s all-in-one computing delivery unit for all scenarios, integrating liquid cooling racks, CDU, power distribution, cooling, fire protection and intelligent management into a standard container. Fully pre-assembled and pre-commissioned at the factory, it starts producing compute as soon as power and water are connected on site, compressing the construction cycle of a traditional data center from months to days — “when the container arrives, computing arrives.”
It suits blockchain mining farms, AI/HPC data centers and edge computing, and can be deployed outdoors or combined in multi-container configurations for on-demand scaling. With customized protection for different climates worldwide, it has been delivered at scale in Ethiopia, the United States and Uzbekistan, making it the flagship fast-deployment product of the Xinke “Computing Ark” series.
Key Features
01 Modular All-in-One Integration, Plug-and-Play: Racks, CDU, power distribution, cooling, fire protection and management systems fully integrated in a standard container, pre-assembled and jointly commissioned at the factory; on-site commissioning within 5 days, drastically cutting construction time and field work.
02 Indoor & Outdoor All-Scenario Deployment: Standard container structure deployable outdoors or rapidly combined indoors; IP54/IP55-rated enclosure with anti-corrosion and anti-UV coating adapts to mining sites, parks, polar and desert locations without civil works.
03 High-Density Liquid Cooling Capacity: Built-in high-density cold plate liquid cooling racks with primary/secondary loop isolation; dual-CDU, dual-loop architecture allows the left and right sides to operate independently for flexible partial-load and maintenance scenarios, ensuring continuous compute.
04 All-Climate Customization, Global Delivery: Customized for extreme climates such as Ethiopian heat, US Midwest winters and Uzbek dry sandstorms: dust-proof, frost-proof and anti-condensation designs with wide-temperature operation from -40°C to +50°C.
05 Multi-Model Compatibility, Hybrid Deployment: Supports mixed configurations of Antminer, Whatsminer and Avalon miners, with air-cooled and liquid-cooled equipment co-located in one box to maximize space and power utilization for evolving and heterogeneous fleets.
06 Smart Management, Unattended Operation: Optional XINKE SMART for integrated control of liquid cooling, power and HVAC, with whole-site sensing, remote on/off, leak warning and energy analysis, 24/7 unattended operation.
07 Modular Expansion, On-Demand Scaling: Standard boxes support parallel combination, scaling smoothly from a single-box mine to a hundred-box computing park; optional DC/AC power supply versions fit different power environments.
08 Precision Manufacturing, Full-Lifecycle Service: ISO9001 quality system with four-stage inspection and ±0.1mm key-dimension precision; 2-year warranty with 7×24 response and 365-day free on-site service in China, with dedicated teams supporting overseas deployment.
Technical Specifications
| Parameter | Specification |
| Container Size | 20ft / 40ft / 45ft standard container (customizable) |
| Bay Capacity | Customized per project; supports mixed Antminer / Whatsminer / Avalon models |
| Unit Power | MW-level, customized per project (multi-container expansion supported) |
| Cooling Method | Cold plate liquid cooling (customized per project) |
| CDU Architecture | Dual-CDU, dual-loop supported, left/right independent operation (480-bay model) |
| Heat Rejection Form | Dry cooler / closed cooling tower / integrated cooling station (customized) |
| Protection Rating | IP54 / IP55 (customizable) |
| Power Supply | Optional DC / AC versions |
| Smart Management | Optional XINKE SMART intelligent management system |
| Deployment Cycle | Factory pre-commissioned; on-site commissioning ≤ 5 days |
| Ambient Operating Range | -40°C ~ +50°C (customizable) |
| Warranty | 2 years, 7×24 service response |
Note: Typical configuration parameters; the final specification is subject to the customized project solution.
Working Principle & System Positioning
The Computing Container integrates IT compute with infrastructure in one enclosure: server heat is transferred to the primary-loop coolant via cold plates, the CDU plate heat exchanger passes the heat to the secondary loop, and outdoor dry coolers, closed cooling towers or integrated cooling stations reject the heat to the environment; in-box power distribution and intelligent management ensure power, cooling and monitoring work in concert. Connected to utilities, it produces compute immediately, and multiple containers can be combined into a micro data center or computing park — a modular, relocatable and replicable way to build computing infrastructure.
Applications
- Rapid deployment and relocation of blockchain mining farms (Ethiopia, Central Asia, US projects)
- Modular expansion of AI / HPC intelligent computing centers
- Temporary, emergency and edge computing nodes
- Computing construction in water-scarce, high-temperature, severe-cold and sandstorm regions
- Rapid computing rollout for site changes and time-sensitive demand
Services & Warranty
- 2-year warranty with 7×24 service response
- 365-day free on-site service in China, covering the full project lifecycle
- Fully customizable: form factor, features, appearance and piping layout
- Standard products delivered in 7-15 days; large custom projects in 30-45 days
- Products delivered to 30+ countries and regions worldwide