Whatsminer 2.5MW Indoor Modular Liquid Cooling Solution

2.5MW indoor modular liquid cooling for Whatsminer water-cooled servers. Large-scale mining thermal management. Complete heat dissipation solution. Request a proposal.

MW-Level Indoor Liquid Cooling — Modular Deployment · Efficient Heat Exchange · On-Demand Expansion

Product Overview

The Whatsminer 2.5MW Indoor Liquid Cooling Module is Xinke Intelligent’s MW-level indoor liquid cooling solution for Whatsminer-series mines, purpose-built for Whatsminer 2U water-cooled servers and carrying 2.5MW-class computing loads in modular form for various indoor sites. With the pump station and control cabinet integrated in the module and a high-efficiency heat exchange design, it delivers stable, precise and efficient liquid cooling for Whatsminer miners — the ideal choice for MW-level indoor liquid cooling construction in small-to-medium mining farms.

Core piping uses 304 stainless steel seamless pipe with a water-electricity isolation design for full safety and stability; optional XINKE SMART provides remote monitoring, leak warning and energy analysis for unattended operation. Multiple modules combine in parallel and expand on demand, working with Whatsminer cabinets and containers to cover every scenario from single modules to scaled deployment.

Key Features

01 2.5MW Power Class, MW-Level Computing Capacity: Modularly carries 2.5MW-class computing loads purpose-built for Whatsminer 2U water-cooled servers, using MW-level heat rejection to support scaled indoor liquid cooling deployment.

02 Custom-Engineered for Whatsminer, Stable & Efficient Heat Exchange: Heat exchange optimized for Whatsminer 2U water-cooled servers keeps temperatures stable under full load, protecting long-term, reliable miner operation.

03 Modular Deployment, Fits Various Indoor Sites: Modular structure fits various indoor sites without large-scale computer room renovation, completing deployment quickly and adapting flexibly to different mining environments.

04 Integrated Pump Station & Control Cabinet, All-in-One Design: The pump station and control cabinet are integrated in the module, eliminating separate pump rooms and distribution cabinets for simpler deployment and O&M.

05 Water-Electricity Isolation Design, Safe Operation: Water and electrical circuits are physically isolated to eliminate cross-contamination safety hazards, protecting miners and operators through high-intensity, long-duration operation.

06 304 Stainless Steel Seamless Piping, Clean & Contaminant-Free: Core piping in 304 stainless steel seamless pipe keeps the system clean, corrosion-resistant and contaminant-free, with no scaling or leakage over time.

07 Multi-Module Parallel, On-Demand Expansion: Supports parallel combination of multiple modules, expanding on demand as computing grows; coordinates with Whatsminer cabinets and containers to build a complete liquid cooling system.

08 Precision Manufacturing, Full-Lifecycle Service: ISO9001 quality system with four-stage inspection and ±0.1mm precision; 2-year warranty with 7×24 response and 365-day free on-site service in China.

Technical Specifications

Parameter Specification
Product Positioning Indoor liquid cooling module (for Whatsminer 2U water-cooled servers)
Power Class 2.5MW (customized per project)
Compatible Models Whatsminer 2U water-cooled servers
Installation Form Modular indoor deployment, multi-module combination
Heat Exchange Design Integrated pump station/control cabinet, high-efficiency heat exchange
Piping Material 304 stainless steel seamless piping (clean, corrosion-resistant)
Safety Design Water-electricity isolation, physically separated circuits
Smart Management Optional XINKE SMART (unattended)
Safety Protection Optional leak detection and alarm
Expansion Multi-module parallel, on-demand scaling
Delivery Cycle 7-15 days for standard products
Warranty 2 years, 7×24 service response

Note: Typical configuration parameters; the final specification is subject to the customized project solution.

 

Working Principle & System Positioning

The Whatsminer 2.5MW Indoor Module connects 2U water-cooled servers into a cold plate liquid cooling loop: server heat is transferred to the coolant via cold plates, 304 stainless steel seamless piping delivers the coolant to the integrated pump station, and outdoor heat rejection terminals dissipate it to the environment; water-electricity isolation ensures electrical safety and the smart management system monitors temperature, pressure and flow in real time. Multiple modules combine in parallel to scale further — the modular solution for indoor liquid cooling construction and expansion in Whatsminer mines.

Applications

  • Scaled indoor liquid cooling deployment of Whatsminer-series miners
  • Liquid cooling retrofit of Whatsminer 2U water-cooled servers
  • MW-level liquid cooling construction for small-to-medium mining farms
  • Phased construction and modular expansion of mining farms
  • Standardized mining facility construction

Services & Warranty

  • 2-year warranty with 7×24 service response
  • 365-day free on-site service in China, covering the full project lifecycle
  • Fully customizable: form factor, features, appearance and piping layout
  • Standard products delivered in 7-15 days; large custom projects in 30-45 days
  • Products delivered to 30+ countries and regions worldwide

Contact Us

Hotline: 400-106-2272

Email: sales@xinkelcs.com

External dimensions
L:7200mm、W:3100mm、H:2600mm
Internal dimensions
L:7100mm、W:3000mm、H:2500mm
Weight
6000KG
Installed capacity
240
PCS
Installed powerload
2400
KW
Power of the light-duty vertical multistage pump
30
KW
Power of the fluid replenishing pump
0.2
KW
Total power of the dry cooling tower fan
58.1
KW
Total power of the closed cooling tower fan
22.5
KW
Total power of the closed cooling tower spray pump
7.5
KW
System pipeline pressure
0.2-0.4
MPA
Operating temperature range of the system
0-50
Coolant circulation demand of a single machine
≥0.6
m³/h
Total demand for circulating coolant within the system
≥0.25
Residual Current Circuit Breaker
400
A
Contactor
9
A
Intermediate relay
24
V
CUL certified frequency converter
380
V
Price:

$40,000.00